| | | ZMPT101B_1X_320 | ||
| 160 kΩ | | 160 kΩ | ||
| 100 Ω | | 100 Ω | ||
| 0.625 mV/V | | 0.625 mV/V | ||
| | | 320V | ||
| | | | ||
|- | |- | ||
| | | ZMPT101B_1X_1000 | ||
| | | 67 kΩ | ||
| | | 100 Ω | ||
| | | 1.493 mV/V | ||
| | | 1000V | ||
| | | | ||
|- | |- | ||
|} | |} |
Revision as of 15:09, 28 January 2020
ZMPT101B Module converts AC Voltage to lower AC Voltage suitable for connection with our RPICT units.
This module shows greatly improved linearity features.

Connections
- Input AC has terminal connector
- Output AC has Jack power type
Mechanical
- Dimensions: 45x30mm height 23mm.
- 2 Hole 25mm appart for Din Rail mounting
Technical Spec
Name | Input Resistor | Output Resistor (Ω) | Sensitivity | Max Range | Calibration Coefficient (theoretical) |
---|---|---|---|---|---|
ZMPT101B_1X_320 | 160 kΩ | 100 Ω | 0.625 mV/V | 320V | |
ZMPT101B_1X_1000 | 67 kΩ | 100 Ω | 1.493 mV/V | 1000V |