RPICT4T4
This page is for board specific information. More information can be found on the generic page for RPICT series.
- 4x AC Current Sensors
- 4x DS18B20 Temperature Sensors
- Attiny84 Mcu
Current Sensor
Recommended sensor: SCT-013-000
Burden Resistor: 24 Ohm
Connector: 3.5mm Jack
Default Voltage for power calculation: 240V (can be modified in firmware).
For AC current only.
Temperature Sensor
Connector: 3.5mm Jack
The intended temperature sensor is the DS18B20.
The connector is a 3 way screw terminal connector.
Configuration
Starting from sketch version 1.4 the RPICT4T4 is configured over serial.
See general instructions for configuration over serial.
Emoncms Config (Emonhub)
For default configuration.
 [[11]]
   nodename = RPICT4T4
   hardware = RPICT4T4
   [[[rx]]]
       names = Power1, Power2, Power3, Power4, T1, T2, T3, T4
       datacode = 0
       scales = 1,1,1,1,1,1,1,1
       units = W,W,W,W,C,C,C,C
Python Example
Please note the uploaded sketch must have CSV enabled. The example script below will be a good starting point.
First of all make sure you have python-serial package installed
$ sudo apt-get install python-serial
Then copy the following into an executable file and run it.
#!/usr/bin/python
import serial
ser = serial.Serial('/dev/ttyAMA0', 38400)
try:
       while 1:
               response = ser.readline()
               z = response.split(",")
               if len(z)>6:
                       print "Power 1: %s Watts" % z[0]
                       print "Power 2: %s Watts" % z[1]
                       print "Power 3: %s Watts" % z[2]
                       print "Power 4: %s Watts" % z[3]
                       print "Temperature 1: %s C" % z[4]
                       print "Temperature 2: %s C" % z[5]
                       print "Temperature 3: %s C" % z[6]
                       print "Temperature 4: %s C" % z[7][:-2]
except KeyboardInterrupt:
       ser.close()